Siirry sisältöön

Hakutulokset

Hakutulokset

Haulla "264" löytyi 151 tulosta.

SFS-EN 62264-3:2017:en – Enterprise-control system integration – Part 3: Activity models of manufacturing operations management

Verkkokaupan tuotteet
It defines activity models of manufacturing operations management that enable enterprise system to control system integration. The activities defined are consistent with the object models definitions given in IEC 62264-1. The modelled activities operate between business planning and logistics fun ...
https://sales.sfs.fi/julkaisu.html.stx?id=482709

SFS-EN 50264-3-2:en – Railway applications – Railway rolling stock power and control cables having special fire performance – Part 3-2: Cables with crosslinked elastomeric insulation with reduced dimensions – Multicore cables

Verkkokaupan tuotteet
EN 50264-3-2 specifies requirements for, and constructions and dimensions of, multicore cables of the following types and voltage ratings: • 300/500 V screened or unscreened (1 mm2, 1,5 mm2 and 2,5 mm2, number of cores from 2 to 40); • 0,6/1 kV screened or unscreened, (1,5 mm2 to 50 mm2, 2, 3 ...
https://sales.sfs.fi/julkaisu.html.stx?id=291705

SFS-EN 50264-3-1:en – Railway applications – Railway rolling stock power and control cables having special fire performance – Part 3-1: Cables with crosslinked elastomeric insulation with reduced dimensions – Single core cables

Verkkokaupan tuotteet
EN 50264-3-1 specifies requirements for, and constructions and dimensions of, single core cables of the following types and voltage ratings: • 0,6/1 kV unscreened, unsheathed (1 mm2 to 400 mm2); • 1,8/3 kV unscreened, unsheathed (1,5 mm2 to 400 mm2); • 1,8/3 kV unscreened, sheathed (1,5 mm2 ...
https://sales.sfs.fi/julkaisu.html.stx?id=291704

SFS-EN 50264-2-2:en – Railway applications – Railway rolling stock power and control cables having special fire performance – Part 2-2: Cables with crosslinked elastomeric insulation – Multicore cables

Verkkokaupan tuotteet
EN 50264-2-2 specifies requirements for, and constructions and dimensions of, multicore cables of the following types and voltage ratings: • 300/500 V screened or unscreened (1 mm², 1,5 mm² and 2,5 mm², number of cores from 2 to 40); • 0,6/1 kV screened or unscreened (1,5 mm² to 50 mm², ...
https://sales.sfs.fi/julkaisu.html.stx?id=291703

SFS-EN 50264-2-1:en – Railway applications – Railway rolling stock power and control cables having special fire performance – Part 2-1: Cables with crosslinked elastomeric insulation – Single core cables

Verkkokaupan tuotteet
EN 50264-2-1 specifies requirements for, and constructions and dimensions of, single core cables of the following types and voltage ratings: • 0,6/1 kV unscreened, unsheathed (1 mm² to 400 mm²); • 1,8/3 kV unscreened, unsheathed (1,5 mm² to 400 mm²); • 1,8/3 kV unscreened, sheathed (1,5 ...
https://sales.sfs.fi/julkaisu.html.stx?id=291702